General Features: Cable composition: – 0.55 mm² conductors, –
Self-adjusting conductive core, – Polyolefin insulating sheath, – Braided
copper sheath, – Outer sheath in modified polyolefin; Minimum room temperature
withstood -35 °C; Maximum room temperature powered 65 °C; Maximum room
temperature not powered 80 °C; Minimum storage room temperature -20 ÷ -25°C; Maximum
length of the heating circuit from the supply point 110 m
Electric Features: Power supply 230V-50Hz; Power delivered ~15W/m
at 5°C; Calibration of the protection circuit 16A x 100 mt at 0°C